Technical Standards
Adherence to FBC TAS 201, 202, and 203 for impact and pressure. Motorized deployments must feature manual overrides for life-safety compliance.
Coastal Durability
Tracks and housings must be cleared of salt-calcification to prevent motor strain and curtain jams. Stainless steel hardware is required for all anchor points.
Maintenance Protocol
Bi-annual operation of all motorized and manual shutters. Lubrication of tracks with dry-film silicone to prevent debris attraction.
Hurricane Shutter Maintenance
Mechanical verification and preservation of life-safety storm protection systems.
Hurricane shutters are complex mechanical systems exposed to the harshest elements on earth. In the Palm Beach climate, a shutter system that isn't exercised regularly will likely fail during a storm deployment due to salt-air corrosion, insect nesting, or motor seizure.
Mechanical Service Standards
- Track Clearance: Lower tracks (especially for Accordion shutters) must be vacuumed and pressure-washed to remove sand and salt crystals that grind down rollers.
- Dry-Lube Application: Never use WD-40 or grease; these attract dust. Use only specialized dry-film silicone or Teflon sprays to ensure smooth movement.
- Motor Torque Testing: Roll-up motors should be tested for "limit switch" accuracy and sound profile—grinding noises often indicate an impending capacitor failure.
- Lock & Bolt Verification: For manual panels and accordions, the locking "slugs" and thumb-turns must be lubricated to ensure they don't seize in the open position.
Frequently Asked Questions
How often should I test my motorized shutters?
Ideally, once every 90 days. Frequent use prevents the motor brushes from "flat-spotting" and ensures the curtain slats remain flexible.
What is "Accordion Seizure"?
This occurs when salt air reacts with the aluminum tracks, creating a white oxidation powder that acts like glue, making it impossible to pull the shutters closed.
Do I need a battery backup?
Yes. If your shutters are motorized and your power goes out before the storm hits, you may be trapped or unprotected. A battery backup or manual crank override is essential.
System Integrity
A shutter system is only as strong as its anchors. We recommend a "Pull-Test" on leading-edge anchors every two years to ensure the substrate hasn't weakened.